Have you ever wondered why some industries require such strict cleanliness standards? Clean room design plays a vital role in maintaining sterile and controlled environments.
From pharmaceuticals to electronics, the right clean room classification ensures that your production processes meet industry standards and avoid contamination.
In this post, you’ll learn about clean room classifications, from ISO 1 to ISO 9, and why choosing the correct one is crucial for your industry. We’ll explore how understanding your specific industry needs helps you select the ideal clean room design.
Clean room design is the process of creating environments that minimize contamination and control environmental factors. The primary purpose of clean room design is to maintain a controlled space where specific cleanliness levels are upheld, crucial for industries like pharmaceuticals, biotechnology, and electronics.
By preventing contaminants from entering the workspace, clean rooms support product quality, ensuring safe production processes and compliance with regulatory standards.
Clean rooms are classified based on the number and size of particles allowed per cubic meter of air. Two main systems exist: ISO 14644-1, used internationally, and the older FS 209E system. ISO classifies clean rooms from ISO 1 (the cleanest) to ISO 9, while FS 209E offers a more granular approach, such as Class 1,000 and Class 100,000.
Classification depends on particle count—how many particles of specific sizes (like 0.3 microns or larger) are present. ISO 14644-1 standards define the maximum allowed concentration of particles based on room classification.
Airflow System: The choice of filtration is crucial. HEPA filters remove 99.97% of particles larger than 0.3 microns, while ULPA filters capture 99.999% of even smaller particles.
Environmental Factors: Temperature, humidity, and pressure must be precisely controlled to ensure consistent quality and prevent contamination.
Materials Selection: Clean room walls, floors, and ceilings are designed with materials like HDPE and FRP, known for their smoothness and ease of cleaning, which help maintain cleanliness.
Industry-Specific Standards: Compliance with regulations such as FDA, EU GMP, and USP ensures clean room designs meet the strict requirements for various industries, ensuring safety and sterility in processes.

Pharmaceutical Industry:
Pharmaceutical cleanrooms must meet ISO 5 or ISO 7 classifications. These standards ensure the environment is free from contaminants, which is essential in drug manufacturing to protect both the products and patients.
Medical Device Manufacturing:
Medical device cleanrooms often require ISO 5 or ISO 6 classifications. These classifications prevent infection risks and maintain the sterility necessary for device production, particularly for implants and surgical tools.
Semiconductor and Electronics:
To protect sensitive equipment, semiconductor and electronics manufacturing often requires ISO 1 or ISO 2 cleanrooms. These classifications minimize contamination that could lead to defects in circuits and other delicate components.
Aerospace and Automotive:
In industries like aerospace and automotive, ISO 7 and ISO 8 cleanrooms are typically used. These classifications help reduce contamination during the assembly and production of components, ensuring high-quality and functional products.
Biotech and Research Labs:
Biotech and research labs need cleanrooms tailored to specific needs. The classification level depends on the experiments and processes. Higher classifications may be required to maintain sterility and prevent contamination from particulates.
Critical Processes Requiring Higher Classifications (e.g., Drug Production, Medical Devices):
For industries where the highest level of contamination control is needed, such as drug production and medical device manufacturing, higher cleanroom classifications like ISO 5 or ISO 6 are essential to protect the product integrity.
Less Stringent Applications (e.g., Assembly, Packaging):
In applications such as assembly or packaging, where the risk of contamination is lower, ISO 7 or ISO 8 cleanrooms may be sufficient. These classifications provide adequate contamination control without the higher costs associated with stricter standards.
ISO 5 Design Features:
Pharmaceutical cleanrooms often require ISO 5 classifications. This includes features like airlock designs to prevent contaminants from entering, gowning areas for personnel, and optimized airflow systems to maintain sterility.
Regulatory Standards:
Clean room design must adhere to FDA regulations, GMP guidelines, and rigorous validation processes to ensure compliance and ensure drug safety.
Key Challenges:
Pharmaceutical cleanrooms face high compliance demands, material compatibility issues, and maintaining a consistently sterile environment. Design must address all these challenges to avoid contamination.
ISO 5 and 6 Designs for Precision Manufacturing:
Medical device cleanrooms must provide sterile environments for manufacturing precision equipment. Cleanroom designs focus on preventing contamination to protect both products and patients.
Airflow and Material Requirements:
To maintain sterility, air filtration systems need to be top-notch, while non-porous surfaces are crucial to prevent the buildup of dust or contaminants that could impact device functionality.
ISO 1 or ISO 2 Designs:
The cleanroom design for semiconductor manufacturing must meet ISO 1 or ISO 2 standards. These ultra-clean environments are essential to protect delicate equipment during chip production.
Challenges in Design:
Key design challenges include minimizing static charges and preventing particulate contamination, both of which could damage sensitive components.
ISO 7 or ISO 8 Cleanrooms:
These cleanrooms are suitable for industries like electronics and aerospace, where contamination control is necessary, but not as stringent as for pharmaceuticals. These classifications provide adequate protection for sensitive equipment.
Design Considerations:
The design focuses on minimizing dust and static, maintaining air circulation, and ensuring an efficient filtration system to prevent contamination of electronic and aerospace components.
Site Evaluation and Clean Room Planning:
The first step in clean room design is evaluating your site to determine the appropriate size, layout, and materials. This planning phase ensures that your clean room meets the needs of your processes while adhering to required classifications.
System Design:
Choosing the right air filtration system is crucial. Depending on your clean room’s classification, you may need HEPA or ULPA filters. Additionally, the layout design should allow for smooth air circulation, and construction materials like FRP walls and vinyl floors ensure easy cleaning and compliance with standards.
Regulatory Compliance:
It’s essential to design your clean room to meet standards such as ISO 14644-1, GMP, and FDA regulations. Compliance ensures your cleanroom operates within the required cleanliness levels and prevents costly issues down the line.
How to Test Your Clean Room Classification:
To verify your clean room’s classification, you’ll need to perform particle count testing and measure air changes per hour (ACH). Certification bodies like ISO and GMP provide the necessary tests to confirm your clean room meets the required standards.
Maintaining Clean Room Standards:
Clean room maintenance includes regular inspections, replacing air filters, and conducting employee training. These practices ensure that your clean room continues to meet required standards and functions effectively over time.
Cost vs. Compliance:
One of the biggest challenges in clean room design is balancing the cost of achieving a higher classification against compliance requirements. Higher classifications like ISO 1 or ISO 2 demand more complex air filtration systems and stricter design features, which can drive up costs. It’s essential to weigh the financial implications against the operational benefits of a cleaner environment.
Customization Needs:
Industries such as pharmaceuticals often require more tailored clean room designs. For instance, these facilities need specific airflow systems, airlocks, and gowning areas to meet stringent sterility requirements. Clean room design must accommodate these unique needs while maintaining efficiency and compliance.
Energy Efficiency and Sustainability:
Clean room design isn’t just about compliance; it’s also about creating an energy-efficient space. Striking a balance between maintaining a clean environment and minimizing energy consumption is key. Implementing energy-efficient HVAC systems, LED lighting, and sustainable materials helps reduce operational costs while meeting clean room standards.
Airflow Disruptions:
Airflow problems can compromise the positive pressure required in clean rooms. Common issues include blocked air vents, dirty filters, or poor design choices. To resolve these problems, regular maintenance of air filtration systems is necessary, and airflow direction should be monitored to ensure contamination control.
Material Contamination:
Non-porous surfaces in clean rooms are designed to reduce contamination risks. However, material contamination can still occur due to inadequate cleaning procedures or wear over time. Regular cleaning schedules, combined with the use of appropriate cleaning agents, can help maintain the integrity of surfaces and prevent contamination.
Understanding your industry’s unique needs is crucial when selecting the right clean room classification. Clean room design plays a vital role in achieving compliance and maintaining product integrity.
Partnering with cleanroom experts ensures your design and classification meet all regulatory standards, optimizing your processes.Contact our specialists at Amber for a consultation to design the perfect clean room tailored to your industry needs.
A: The ideal clean room classification depends on your industry. For pharmaceutical manufacturing, ISO 5 or ISO 7 is essential for sterility, while semiconductor and electronics require ISO 1 or ISO 2 for ultra-clean environments. Modular cleanroom construction can be an efficient solution for customizing your clean room to meet these standards.
A: To ensure compliance with ISO 14644 cleanroom standards, you'll need to conduct particle count testing, measure airflow, and verify air changes per hour (ACH). The cleanroom certification process typically involves an assessment by a third-party certifier who checks if your cleanroom design meets ISO 14644-1.
A: Yes, retrofitting your clean room to meet a higher classification may involve adjusting the layout, upgrading the HVAC design, or improving filtration systems. Cleanroom modular design benefits allow flexibility, making modifications easier and more cost-effective.
A: Cleanroom design costs depend on factors like material selection, airflow systems, and regulatory compliance. For example, modular cleanroom construction can lower costs compared to traditional builds, while custom features like high-efficiency air filtration and controlled environments add to the cost.